Skip to main content
  • SLIO

SLIO: Interface modules

Interface modules (IM) form the interface between process level and parent bus system. All control signals are transmitted through the internal backplane bus to the electronics module (EM).

In the case of the interface module the bus interface and power module (PM) are integrated in a single casing. Both the bus interface and the electronics of the connected peripheral modules are supplied with power via the integrated power module.

Up to 64 I/O modules can be operated on the interface module.

Characteristics

Support for various fieldbus systems

Functional DIP switches for address setting for the PROFIBUS-DP and CANopen with transparent cover

MAC address on the front in plain text

Electrical isolation between fieldbus and input/output field

Integrated DC 24 V power module to the electronic and load voltage supply of the peripheral modules

Easy to maintain, replaceable power module

Up to 64 signal and function modules per interface module

24 month warranty


Order no.Name/Description

053-1CA00

IM 053CAN - CANopen slave

CANopen slave
16 Rx and 16 Tx PDOs
2 SDOs
PDO linking
PDO mapping: fix
up to 64 peripheral modules
[Datasheet]
[Manual]
[STP]

053-1DN00

IM 053DN - DeviceNet slave

DeviceNet slave
Group 2 only device
Poll only device
Baud rate: 125, 250 and 500kbit/s
up to 64 peripheral modules
[Datasheet]
[Manual]
[STP]

053-1DP00

IM 053DP - PROFIBUS-DP slave

PROFIBUS-DP slave (DP-V0, DP-V1)
244 Byte input and 244 Byte output data
up to 64 peripheral modules
[Datasheet]
[Manual]
[STP]

053-1EC00

IM 053EC - EtherCAT slave

EtherCAT slave
RJ45 jack 100BaseTX
up to 64 peripheral modules
[Datasheet]
[Manual]
[STP]

053-1IP00

IM 053IP - EtherNet/IP slave

EtherNet/IP-Slave
I/O configuration via fieldbus
up to 64 peripheral modules
[Datasheet]
[Manual]
[STP]

053-1MT00

IM 053MT - Modbus/TCP slave

Modbus/TCP slave
I/O configuration via fieldbus
up to 64 peripheral modules
[Datasheet]
[Manual]
[STP]

053-1PN00

IM 053PN - PROFINET-IO slave

PROFINET-IO slave
Transfer rate 100Mbit/s
up to 64 peripheral modules
[Datasheet]
[Manual]
[STP]

060-1AA00

IM060 Line Extension

SLIO IM060 bus extension
Master module for extension / renewal of the SLIO bus to another line
Connector: 1x RJ45 plug connector
Module width 25.8 mm
Connection: CAT6 cable, maximum length: 2m
Module is always installed at the last place in the line, module IM060 and IM061 always form a pair
[Datasheet]
[Manual]

061-1BA00

IM061 Line Extension

SLIO IM 061 bus extension
Slave module for extending SLIO bus up to 8 additional lines (up to 64 modules)
Connector: 1x RJ45 plug connector
Module width 25.8 mm
Connection: CAT6 cable, maximum length: 2m
Module is always installed at the first place in the line; ␍Module IM 060 and IM 061 always form a pair
[Datasheet]
[Manual]