322-1BL00 - Signal modules digital | Digital output modules
Order no. |
322-1BL00 |
Type | SM 322 |
General information |
|
Note | - |
Features | 32x DO, in groups of 8 DC 24 V 1 A For 40 pole front connector |
SPEED-Bus | - |
Current consumption/power loss |
|
Current consumption from backplane bus | 90 mA |
Power loss | 6 W |
Technical data digital outputs | |
Number of outputs | 32 |
Cable length, shielded | 1000 m |
Cable length, unshielded | 600 m |
Rated load voltage | DC 24 V |
Current consumption from load voltage L+ (without load) | 110 mA |
Total current per group, horizontal configuration, 40°C | 2.5 A |
Total current per group, horizontal configuration, 60°C | 2.5 A |
Total current per group, vertical configuration | 2.5 A |
Output current at signal "1", rated value | 1 A |
Signal logic output | Sourcing output |
Output delay of "0" to "1" | 150 µs |
Output delay of "1" to "0" | 100 µs |
Minimum load current | - |
Lamp load | 5 W |
Parallel switching of outputs for redundant control of a load | possible (only outputs group) |
Parallel switching of outputs for increased power | not possible |
Actuation of digital input | ![]() |
Switching frequency with resistive load | max. 1000 Hz |
Switching frequency with inductive load | max. 0.5 Hz |
Switching frequency on lamp load | max. 1 Hz |
Internal limitation of inductive shut-off voltage | L+ (-45 V) |
Short-circuit protection of output | yes, electronic |
Trigger level | 1.5 A |
Number of operating cycle of relay outputs | - |
Switching capacity of contacts | - |
Output data size | 4 Byte |
Status information, alarms, diagnostics |
|
Status display | green LED per channel |
Interrupts | no |
Process alarm | no |
Diagnostic interrupt | no |
Diagnostic functions | no |
Diagnostics information read-out | none |
Supply voltage display | green LED per group |
Group error display | red SF LED |
Channel error display | none |
Isolation |
|
Between channels | ![]() |
Between channels of groups to | 8 |
Between channels and backplane bus | ![]() |
Insulation tested with | DC 500 V |
Datasizes | |
Input bytes | 0 |
Output bytes | 4 |
Parameter bytes | 0 |
Diagnostic bytes | 0 |
Housing |
|
Material | PPE |
Mounting | Rail System 300 |
Mechanical data | |
Dimensions (WxHxD) | 40 mm x 125 mm x 120 mm |
Net weight | 225 g |
Weight including accessories | 235 g |
Gross weight | 265 g |
Environmental conditions |
|
Operating temperature | 0 °C to 60 °C |
Storage temperature | -25 °C to 70 °C |
Certifications | |
UL certification | yes |
KC certification | yes |